[口頭報告]Experimental study on the fire control and smoke transportation using sealing strategy in tunnel
Experimental study on the fire control and smoke transportation using sealing strategy in tunnel
編號:215
稿件編號:156 訪問權限:僅限參會人
更新:2024-05-15 17:44:30
瀏覽:190次
口頭報告

報告開始:2024年05月31日 16:30 (Asia/Shanghai)
報告時間:10min
所在會議:[S2] Safety Engineering and Occupational Health ? [S2-3B] Afternoon of May 31st B
暫無文件
摘要
Sealing tunnel portals is a favorable approach to controlling tunnel fires. This paper experimentally studied the influence of portals-sealing on fire behavior in a small-scale tunnel. A series of characteristic parameters, including fuel burning rate, O2 and CO2 volume fraction, and ceiling smoke temperature in the tunnel were measured. Besides, the flame self-extinguishment time, smoke transportation characteristics and gas temperature field at different fire source locations and sealing conditions were systematically investigated. Results indicated that the critical equivalence ratio for methanol fuel converted to ventilation-controlled tunnel fires is within 0.783-0.923. The combustion state is influenced by fire location. Fires occurring near the tunnel entrance are more prone to self-extinguishment than those away from the tunnel entrance. The critical volume fraction of O2 for flame self-extinguishment ranges from 13.5%-15.3% and decreases with increasing smoke temperature. Moreover, sealing tunnel portals significantly impacts peak smoke temperature values, but hardly changes the longitudinal distribution pattern of temperature. The longitudinal distribution model of gas temperature under the action of the strong plume in a confined space is developed. This study provides guidance for fire risk assessment during the tunnel sealing process and contributes to the scientific development of sealing strategies.
關鍵字
tunnel fire; sealing effect; equivalence ratio; flame self-extinguishment; smoke transportation characteristics
報告人

發表評論