• [口頭報告]Design and evaluation of filter membrane belt dust mass concentration detection instrument based on the coupling principle of light scattering and light absorption
    00
    days
    00
    hours
    00
    minutes
    00
    seconds
    00
    days
    00
    hours
    00
    minutes
    00
    seconds

    [口頭報告]Design and evaluation of filter membrane belt dust mass concentration detection instrument based on the coupling principle of light scattering and light absorption

    Design and evaluation of filter membrane belt dust mass concentration detection instrument based on the coupling principle of light scattering and light absorption
    編號:193 稿件編號:213 訪問權限:僅限參會人 更新:2024-05-19 11:24:51 瀏覽:172次 口頭報告

    報告開始:2024年05月30日 19:40 (Asia/Shanghai)

    報告時間:10min

    所在會議:[S2] Safety Engineering and Occupational Health ? [S2-4A] Evening of May 30th-4A

    暫無文件

    摘要
    Particulate matter in the workplace has a significant impact on environmental pollution and the health of workers. Accurate real-time monitoring of particulate matter concentration is essential for preventing and controlling environmental pollution. In this study, a new type of dust mass concentration detection instrument based on the coupling principle of light scattering and light absorption was developed. The instrument integrates light scattering and light absorption detection techniques into the detection device. Building upon the previous empirical formula, the fitting results of the two detection signals were analyzed using F-test and T-test. Finally, a mathematical model of optical signal-mass concentration was established, achieving a fitting R2 of over 0.90. Unlike traditional optical detection instruments, the filter belt optically coupled dust detection instrument can reduce the pollution caused by sampling dust on the optical components and enable automatic replacement of the filter membrane. After experimental verification, the detection model was found to be unaffected by dust type and particle size. A comparative experiment with the standard instrument TSI Dusttrak 8530 demonstrated that the measurement results of this instrument were reliable and stable in the concentration range of 0~300mg/m3, with had practical application value.
    關鍵字
    dust detection,light scattering,light absorption,coal dust,membrane belt type,mass measurement
    報告人
    Chao Chen
    學生 China University of Mining and Technology

    稿件作者
    超 陳 中國礦業大學
    麗娜 鄭 中國礦業大學
    發表評論
    驗證碼 看不清楚,更換一張
    全部評論

    聯系我們

    投稿事宜:張老師
    電話:0516-83995113
    會務事宜:張老師
    電話:0516-83590258
    酒店事宜:張老師
    電話:15852197548
    會展合作:李老師
    電話:0516-83590246
    登錄 注冊繳費 提交摘要 酒店預訂
  • 成人视频