• [口頭報告]A Raman Spectroscopic method for Measuring the Crystalline Silica Content in Coal Dust
    00
    days
    00
    hours
    00
    minutes
    00
    seconds
    00
    days
    00
    hours
    00
    minutes
    00
    seconds

    [口頭報告]A Raman Spectroscopic method for Measuring the Crystalline Silica Content in Coal Dust

    A Raman Spectroscopic method for Measuring the Crystalline Silica Content in Coal Dust
    編號:189 稿件編號:211 訪問權限:僅限參會人 更新:2024-05-19 11:24:00 瀏覽:202次 口頭報告

    報告開始:2024年05月30日 19:30 (Asia/Shanghai)

    報告時間:10min

    所在會議:[S2] Safety Engineering and Occupational Health ? [S2-4A] Evening of May 30th-4A

    暫無文件

    摘要
    To explore the use of Raman spectroscopy in analyzing crystalline silica content within coal dust, the Raman spectroscopy techniques were investigated for quantitative analysis of silica in coal dust samples from China based on unary linear regression (ULR) and partial least squares regression (PLSR) method. In the experimental setup, the formulated coal dust samples with known crystalline silica content were meticulously prepared and subjected to an ashing procedure using a muffle furnace. The cooled mixtures were placed in water for magnetic stirring before being dispensed onto an aluminum substrate via a pipette gun, ultimately forming dry sample deposits. According to the Raman spectrum data from these dry sample deposits, a calibration curve was generated and served as the foundation for predicting crystalline silica content in real coal dust samples. In the quantitative analysis of the crystalline silica load in the formulated coal dust samples deposited within a diameter of about 1 cm, the calibration curve R2 value of the ULR model is 0.90, with a limit of detection (LOD) is 0.96% (i.e., 19.17 μg). Meanwhile, the R2 value of the PLSR model can reach 0.988, and concurrently, the LOD can be reduced to 0.18% (3.65 μg). Moreover, the improved PLSR model, which established with coal dust samples collected from a broader range of geological conditions, demonstrates high accuracy and good agreement between the analysis results of the prediction set and the measurements obtained from the standard infrared (IR) spectrometric method. This study indicates the potential of Raman spectroscopy for measuring crystalline silica in coal dust.
    關鍵字
    coal dust,crystalline silica,quantitative analysis,Raman spectroscopy
    報告人
    Wenting Feng
    China University of Mining and Technology

    稿件作者
    溫婷 馮 中國礦業大學
    麗娜 鄭 中國礦業大學
    穎碩 朱 中國礦業大學
    發表評論
    驗證碼 看不清楚,更換一張
    全部評論

    聯系我們

    投稿事宜:張老師
    電話:0516-83995113
    會務事宜:張老師
    電話:0516-83590258
    酒店事宜:張老師
    電話:15852197548
    會展合作:李老師
    電話:0516-83590246
    登錄 注冊繳費 提交摘要 酒店預訂
  • 成人视频